Products Installation Instructions Sales Reps Distributor Locator Request Info
Installation Instructions
Home About Compotite

 

CTI Bonded Direct/Anti Fracture Test Results

I. BONDED DIRECT / ANTI-FRACTURE TESTS COMPOSEAL GOLD
Test Results
CERAMIC TILE INSTITUTE
Minimum Standard
BOND SHEAR STRENGTH: ASTM C-482 (mod) measures lateral psi at which installation loses bond under wet and dry conditions. using latex mod. Thin set mortar Using dry set mortar
Dry: 3 days cover cured plus 4 days air cured: 71 psi 121 psi 50 psi
3 days cover cured plus 28 days air cured: 78 psi 111 psi 50 psi
Wet: 3 days cover cured, 4 days air cured, PLUS total immersion in water for 7 days: 64 psi 92 psi 50 psi
for 21 days: 63 psi 121 psi 50 psi
for 93 days: 56 psi 95 psi 50 psi
NOTE: Latex modified mortar of ten requires more than 7 days air cure for maximum strength.
TENSILE STRENGTH: CTI/SE 5763
Measures psi pull strength at which installation
loses bond under dry and wet conditions.
Using latex mod. mortar
Dry: 3 days cover cured plus 25 days air cured: 75 psi 50 psi
Wet: 3 days cover cured plus 4 days air cured PLUS 7 days immersed in water: 69 psi 50 psi
21 days immersed in water: 63 psi 50 psi
93 days immersed in water: 54 psi 50 psi

TOTAL SYSTEM PERFORMANCE: ASTM C627 (mod)
Robinson Floor Tester/Split Slab .002 to .008" Tests for integrity of total installation no tile cracking/chipping or grout deterioration after successive cycles of increased load/stress over split substrate. Hydrostatic testing with 2" head of water performed at end of cycles. Number of completed cycles before failures:
11 cycles (Gold adhesive bond)
9 cycles (Mortar bond)
3 cycles
3 cycles

ROBINSON FLOOR TESTER: ASTM C627
(without split slab) Quarry tiles used.
14 cycles: Extra Heavy Commercial Rating

II.

WATERPROOF TEST

HYDROSTATIC: FHA 4900.1 Sect. 615-5
Measures integrity of membrane after being subjected to 2 ft. head of water for 48 hours.
no water
penetration
no water
penetration

INDENTATION RESISTANCE: FHA 4900.1
Tests membrane's chemical resistance to highly alkaline solutions such as soapy water.
no water
penetration
no water
penetration

PUNCTURE RESISTANCE: FHA 4900.1
200 gram dart with small ball bearing point dropped from 3 ft. Simulates dropping of sharp edged tools onto membrane.
no water
penetration
no water
penetration

FOLDING RESISTANCE: FHA 4900.1
Tests membrane for cracking in cold weather: 24o F for 24 hours, then membrane folded back on itself twice and then tested for cracks.
no water
penetration
no water
penetration

FUNGUS and MICRO-ORGANISM RESISTANCE:
FHA 4900.1 plus Sec. C, or ANSI A136.1, K-6.4
Fungus and/or bacterial growth must actively be inhibited by membrane within 24 day period.
no growth and
no water
penetration
no growth and
no water
penetration

DIMENSIONAL STABILITY: ASTM D-1204
, -12o to 212o F
Membrane is tested for lineal change after being heated, and also after being cooled.
length:
width:
-200 F 2120F
-.17% -.35%
-.29% -.30%
.5%
.5%

SEAM STRENGTH: ASTM D-751
COMPOSEAL flexible vinyl cement, 24 hour cure
47.7 psi/in. width 8 psi/in. width

BREAKING STRENGTH: ASTM D-751
Linear pressure at which membrane tears:
parallel : 1517 psi
parallel : 1603 psi
170 psi
170 psi

ELONGATION: ASTM D-751
Amount membrane stretches before breaking:
parallel : 364%
perpend.: 462%
20%
20%

HYDROSTATIC PRESSURE: ASTM D-751, A-1
Measures effect of sudden burst of high water pressure on membrane, such as water pipe burst.  Results give psi at which membrane ruptures.
116 psi 100 psi
BREAKING STRENGTH: ASTM D-751
Linear pressure at which membrane tears:
parallel : 1517 psi 170 psi

III.

OPTIONAL TESTS
(Not required by CTI for Listing)

FLAMMABILITY: ASTM D568-77
Measures rate and extent of burning of bare membrane.  Self extinguished.
Burned .6 sec. after flame removed

OZONE RESISTANCE: ASTM D1149
No crack, crazing or water penetration observed.

GAS PERMEABILITY (Methane) : ASTM D1434
Measures amount of methane gas that permeates membrane.
GTR: 231.ml, Coeff: 3.6 Barrier

VOLATILITY TEST: ASTM D1203-89, Method A
Measures weight loss and distortions after accelerated aging of membrane.
.33% weight loss, no distortion

 

 

 